https://www.eng-tips.com/viewthread.cfm?qid=216801
May 22, 2008 · Vertical Spacing for Pipe Supports NewMechanicalEngr (Mechanical) ... A suggested maximum vertical extension past support might be half of the maximum horizontal span. So approx. 6 ft for NPS-1, 8 ft for NPS-1.5, 10 ft for NPS-2 Loads of seismic, wind, equipment vibration, etc will make the stress situation more complicated for support / length
https://spedweb.com/public-technical/484-supporting-vertical-piping
Hanger spacing charts for horizontal "runs" of pipe are based upon limiting the bending stress in the horizontal piping (and they DO NOT address concentrated loads like large valves). Supporting vertical piping is quite a different thing. How a vertical riser is supported depends greatly …
https://www.commercial-industrial-supply.com/resource-center/pvc-pipe-support-spacing-guide/
Spacing for vertical systems should usually be about two times the intervals in the table above. If you are working on an inspected job, you will also need to be aware of any specific code requirements for pipe support in your area. Supports should at the very …
https://up.codes/s/piping-support
a. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet where 10-foot lengths of pipe are installed. b. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical supports. Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe.
https://www.enggcyclopedia.com/2012/06/spacing-pipe-supports/
For example, the spacing of pipe supports on a 6" line will be approximately 6 + 10 = 16 feet. This spacing changes at high temperatures and for materials other than steel. For example, for copper tubing, support spacing varies from 8-ft for 1" tubing to 12-ft for 4". For PVC pipe the spacing depends on the pipe schedule and operating temperature.
https://www.corzan.com/en-us/piping-systems/installation/maximum-support-spacing
Maximum Support Spacing (ft.) Schedule 80 . Support Spacing for 6-in. Diameter, Schedule 80 Thermoplastic Systems . Maximum Support Spacing (ft.) Schedule 40 . Pipe Hangers, Clamps and Supports Horizontal Piping Hangers and Supports . Corzan ® piping should not be anchored tightly to supports, but rather secured with smooth straps or hangers ...
https://www.engineeringtoolbox.com/support-space-pvc-pipes-d_790.html
PVC Pipes and Support Spacing Distance between support for PVC pipes . Sponsored Links . Maximum distance between PVC - Polyvinyl Chloride - pipes supports depends on operating temperature: ... pvc pipe support space distance ; Sponsored Links . Search the Engineering ToolBox - the most efficient way to navigate the Engineering ToolBox!
https://www.engineeringtoolbox.com/steel-pipe-supports-d_1071.html
Related Topics . Dimensions - Sizes and dimensions of pipes and tubes, and their fittings - inside and outside diameter, weight and more ; Related Documents . Copper Tube Supports - Maximum space between supports aand clips for copper tubes; Hanger Support Spacing - Rod Sizes Horizontal Pipes - Recommended maximum support span between hangers - and rod sizes for straight horizontal pipes
http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/pipe_hangers/pipe_hangers_and_supports/Supports.pdf
Pipe supports offered in this section are designed to support pipe from a base structure where vertical ... pipe supports, B3090, B3094, B3095, B3096, B3097 and B3098, to meet requirements of 12X anchor diameter hole spacing for seismic applications. The standard B3088-3 & B3088-6 already meet this requirement. Finish: Plain or Electro-Galvanized.
https://upg.nz/site/assets/files/1179/013_stream_pe_100_pipe_support_spacings.pdf
PE 100 PIPE SYSTEMS PIPE SUPPORT SPACINGS As polyethylene is a flexible material, adequate pipe supports must be provided for pipes installed in above ground applications TABLE 7 ABOVE GROUND PIPEWORK MAX SUPPORT SPACING (Meters) Pipe Diameter (mm) SDR 26 SDR21 SDR17 SDR13.6 SDR 11 SDR 9 SDR 7.4 20 25 0.70 0.75 0.70 0.80 32 40 0.75 0.90
How to find Vertical Pipe Support Spacing information?