https://www.pexuniverse.com/providing-proper-support-long-runs-pex-tubing
Long runs of PEX pipe have to be supported with proper hangers. It is generally recommended to fasten the tubing at every 32 inches when running it alongside a joist and at least every 6 feet if the tubing is supported by beams and running across them.
https://www.arcat.com/cad/uponorwi/221116_04_sa_d_supporting-pipe-and-fittings-detail.pdf
Horizontal Support Spacing Requirements for Uponor PEX Pipe: A B Maximum Allowable Support Spacing for Bare-PEX Pipe Maximum Allowable Support Spacing for PEX Pipe with PEX-a Pipe Support A A A/2 A/2 Additional Support G G H H Corner Support Example Distance G = 16" Total distance for G = 32" (16 + 16) Distance H = > 16" Total distance for H ...
http://www.uponorpro.com/~/media/Extranet/Files/manuals/PEX-aPipeSupport_IS_P462_0912.aspx?sc_lang=en
to PEX-a Pipe Support Pipe Size Minimum Distance 1" 2¼" 1¼" 2¾" 1½" 3" 2" 4" C Maximum Distance Between PEX-a Pipe Supports Application Maximum Distance Non-plenum Rated 1" pipe 1¼" to 2" pipe 32" for IPC/UPC 32" for IPC 48" for UPC Plenum Rated 10" E Strapping Requirements for Clamps and Hanger Applications Application Maximum Distance
https://www.uponorengineering.com/~/media/extranet/files/2014%20ic%20bundled%20launch/vld%20pipe%20support/pex-apipesupport_is_69402_0516.ashx?version=062120160256
PEX-a Pipe Support instruction sheet PEX-a Pipe Support is a 23-gauge, galvanized-steel channel for PEX piping with a CTS (copper tube size) controlled outside diameter. It features a profile that is more than half-round, making it self-gripping. It provides continuous support of PEX piping, allowing increased hanger spacing compared to bare PEX.
http://www.uponorpro.com/~/media/Extranet/Files/manuals/PEX-aPipeSupport_IS_P756_0614.aspx?sc_lang=en&version=062620140338
Maximum support distance from center of fitting to PEX-a Pipe Support end is 18". PEX-a Pipe Support Installations in ASTM E84 Applications Strapping for Systems using Clevis-type Hangers or Equivalent Strap within 1" of hanger Strap at mid-span Clevis hanger PEX-a Pipe Support Strapping for Systems using Strut-clamps or Equivalent Strap at mid-span
http://www.uponor-usa.com/~/media/Extranet/Files/plumbing%20literature/PEX-aPipeSupport_IS_P462_10122.aspx?sc_lang=en
B Maximum distance from clamp/hanger to end of PEX-a Pipe Support is 18".
https://www.uponorengineering.com/~/media/extranet/files/manuals/uponor%20piping%20pocket%20guide.ashx?version=062520180424
Uponor PEX bend radius The minimum bend radius of Uponor AquaPEX pipe is six times the outside diameter. Bend supports are available for ⅜", ½", ¾" and 1" piping and may be used to facilitate 90-degree rigid bends. Use large-diameter PVC conduit to facilitate 90-degree bends in larger-diameter Uponor PEX piping. Table 2: Bending Uponor PEX Pipe
https://www.doityourself.com/stry/pex-tubing-installation-dos-and-donts
For example, a 1/2-inch tube can have a three inch bend radius. All 90-degree turns should have bend supports. Do Know How Deep to Drill or Notch. With PEX tubing installation, drill to a maximum depth of 40 percent the depth of the wood on load bearing wood- …