https://www.engineeringtoolbox.com/piping-support-d_362.html
PVDF Pipes - Support Spacing - Maximum distance between PVDF pipes supports; Steam Pipes - Sizing - Pipe sizing steam systems - major and minor loss in steam distribution systems; Steel Pipe Supports - Recommended distance between steel pipe supports ; Support Spacing ABS, PE, PVC, Fiberglass and Steel Pipes - Maximum distance between supports ...
https://www.engineeringtoolbox.com/steel-pipe-supports-d_1071.html
Recommended distance between steel pipe supports . Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! - the most efficient way to navigate the Engineering ToolBox! Steel Pipe Supports
https://www.sikla.com/fast/600/Installation%20Guideline%20Pipe%20Support.pdf
Support distances in building services for pipes made of steel, copper, plastic (standard values) 18.2 Support distances for plastic pipes (standard values according to producer) 18.3
https://www.enggcyclopedia.com/2012/06/spacing-pipe-supports/
For fiber reinforced plastic pipe (FRP), support spacing in liquid service would vary from around 11-ft for 2" pipe to 22-ft for 8" pipe; and for gas service 17-ft for 2" to 40-ft for 8". For high density polyethylene (HDPE) the spacing would vary from 7-ft for 4" pipe with SDR …
https://www.engineeringtoolbox.com/support-space-pvc-pipes-d_790.html
PVC Pipes Schedule 40 - Friction loss and Velocity Diagrams - Friction loss (psi/100 ft) and velocity for water flow in plastic PVC pipe schedule 40 ; Thermoplastic Pipes - Temperature and Support Distance - Maximum space between supports for PVC, CPVC, PVDF and PP pipes
http://www.wermac.org/pdf/steel3.pdf
distance between supports will minimize the number of supports required, which in turn reduce the total cost of erecting these pipe supports. ASME has suggested the standards for support span, but the bending stress considered in its calculation is very low (15.9 Mpa). There are other references also who have listed the maximum support span.
http://www.kws-industrietechnik.de/rohrlager-abstand-gb-inet.pdf
www.kws-industrietechnik.de Tel +49 (0) 7731 91 93 00 Fax +49 (0) 7731 91 93 01 Pipe support distance Max. distances of the pipe supports in meters depend on temperature, fluid and type of pipe