https://www.engineeringtoolbox.com/piping-support-d_362.html
Epoxy Pipes - Support Spacing - Support spacing for reinforced Epoxy fiberglass pipes; Piping Elbows - Thrust Block Forces - Thrust block forces on pipe bends anchor due to liquid velocity and internal pressure - online resulting force calculator; PP Pipes - Support Spacing - Maximum distance between PolyPropylene pipes supports
https://aquatherm.com/hanger-spacing-chart
Hangers PP-R Pipe Hanger Spacing & Clamp Sizes. Aquatherm pipe is much lighter than metal pipe so the hanger spacing requirements are different. Please note that hanger spacing should be based on the intended temperature of the pipes. Metric supports and clamps are available, and should be used whenever possible.
https://www.enggcyclopedia.com/2012/06/spacing-pipe-supports/
For example, the spacing of pipe supports on a 6" line will be approximately 6 + 10 = 16 feet. This spacing changes at high temperatures and for materials other than steel. For example, for copper tubing, support spacing varies from 8-ft for 1" tubing to 12-ft for 4".
https://www.guenthersupply.com/pdf/hanger-spacing-weight-chart.pdf
* Many codes require pipe hangers to be spaced every 10 ft. regardless of 1 Cubic Ft. of water weighs 62.41 lbs.
https://www.pipeshields.com/products/table3.htm
Pipe Shields. Manufacturers of insulated pipe supports, hot shoes and cold shoes since 1971
https://www.engineeringtoolbox.com/support-space-pvc-pipes-d_790.html
Hanger Support Spacing - Rod Sizes Horizontal Pipes - Recommended maximum support span between hangers - and rod sizes for straight horizontal pipes; ISO 11922 - Thermoplastics pipes for the conveyance of fluids - Dimensions - Dimensions of plastic pipes according ISO 11922 - …
https://up.codes/s/piping-support
The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet where 10-foot lengths of pipe are installed.
https://www.commercial-industrial-supply.com/resource-center/pvc-pipe-support-spacing-guide/
You’ll find that your support needs vary from system to system based on configuration, pipe size, load, and temperature. There are also other things to keep in mind when planning your support. Valves and other points of extra load should be supported separately from your pipe spacing.
https://community.nfpa.org/thread/33940
Nov 07, 2017 · Pipe ring max load = (5 x water-filled weight x spacing) +250 lbs 300 lbs = (5 x 2.05 x spacing) + 250 lbs Resulting spacing is 4.88 ft. It seems crazy to ask for pipe support every 4ft10in, especially since NFPA 13 table 9.2.2.1 says maximum distance between hangers is 12 ft for 1 in pipe.Reviews: 2