Npiv Support Aix 5 3

Searching for Npiv Support Aix 5 3 information? Find all needed info by using official links provided below.


IBM PowerVM NPIV / IBM Switch Configuration

    http://www-01.ibm.com/support/docview.wss?uid=isg3T1012452
    NPIV-enabled SAN switch Only the first SAN switch which is attached to the Fibre Channel adapter in the Virtual I/O Server needs to be NPIV-capable. Other switches in your SAN environment do not need to be NPIV-capable. 2. Software HMC V7.3.4, or later Virtual I/O Server Version 2.1 with Fix Pack 20.1, or later AIX 5.3 TL9, or later AIX 6.1 TL2 ...

Aix Practices: How to configure NPIV (N_Port ID ...

    https://aixpractices.blogspot.com/2011/10/how-to-configure-npiv-nport-id.html
    Oct 24, 2011 · Let s ay I have define the virtual fiber adapter for AIX client Netwqa with adapter ids 33 & client adapter id 33 Similarly on Vios2 for multipath redundancy:- If you have any more LPARs which you want to configure for NPIV, repeat the above mentioned steps with those LPAR details.

IBM PowerHA announces support for NPIV - United States

    http://www-01.ibm.com/support/docview.wss?uid=tss1flash10691
    IBM* PowerHA* (formerly HACMP*) for AIX*, Versions 5.4.1 and 5.5, extends support to include NPIV with the IBM Virtual I/O Server (VIOS) V2.1 virtual SCSI and virtual Ethernet devices on all PowerHA supported IBM POWER5* and POWER6* processor-based servers along with IBM BladeCenter. This includes PowerHA nodes running in IBM AIX LPARs on supported IBM System i5* servers.

IBM Techdocs Flash: PowerHA announces support for NPIV

    https://www-03.ibm.com/support/techdocs/atsmastr.nsf/fe582a1e48331b5585256de50062ae1c/5520d310e881295486257cbb007c7e40
    IBM* PowerHA* (formerly HACMP*) for AIX*, Versions 5.4.1 and 5.5, extends support to include NPIV with the IBM Virtual I/O Server (VIOS) V2.1 virtual SCSI and virtual Ethernet devices on all PowerHA supported IBM POWER5* and POWER6* processor-based servers along with IBM BladeCenter. This includes PowerHA nodes running in IBM AIX LPARs on supported IBM System i5* servers.

N-Port ID (NPIV) Virtualization Support on AIX with SF HA 5.1

    https://www.veritas.com/content/support/en_US/article.100022746.html
    N-Port ID (NPIV) Virtualization Support on AIX with SF HA 5.1 Solution. NPIV and the IBM Virtual I/O Server (VIOS) NPIVOverview: N_PortID Virtualization (NPIV) is a fibre channel industry standard method forvirtualizing a physical fibre channel port. NPIV allows one F_Port to beassociated with multiple N_Port IDs, so a physical fibre channel ...

AIX® Server Requirements and Support

    https://www.ibm.com/support/pages/aix%C2%AE-server-requirements-and-support
    AIX 5.3 running in a 64-bit kernel environment with the following additional requirements: *This is the minimum TL and Service pack level supported by the TSM server. Any TL and SP levels equal or higher than what is listed here is supported AIX 5.3 Technology Level (TL) 11 and Service Pack (SP) 1

vSCSI to vFC (NPIV) migration

    https://www.ibm.com/developerworks/community/wikis/form/anonymous/api/wiki/61ad9cf2-c6a3-4d2c-b779-61ff0266d32a/page/f1abe75a-a2b2-43dd-9d75-7dae28f5bc5f/attachment/07470f4e-b740-4416-a4bc-45d474550649/media/2012-07%20vSCSI%20to%20vFC%20%28NPIV%29%20migration.pptx
    • 8Gb PCIe Dual-port FC Adapter • SAN switch are NPIV enabled• VIOS version 2.1 or above• AIX 5.3 Technology Level 09 or above• AIX 6.1 Technology Level 02 or above. Classified - Internal use. Basic steps when migrating from vSCSI to NPIV ... the HBA port should be already connected to the SAN switch enabled with NPIV support.

NPIV - AIX for System Administrators

    https://aix4admins.blogspot.com/2011/06/virtual-fibre-channel-adapter-nport-id.html
    To enable NPIV on the managed system, you must create a Virtual I/O Server logical partition (version 2.1, or later) that provides virtual resources to client logical partitions. You assign the physical fibre channel adapters (that support NPIV) to the Virtual I/O Server logical partition.

PowerHA v6.1 EE adds support for NPIV w/ EMC SRDF - IBM

    https://www-03.ibm.com/support/techdocs/atsmastr.nsf/fe582a1e48331b5585256de50062ae1c/6fb100bffa66dc0886257cbb007c7dce
    IBM PowerHA SystemMirror V6.1 Enterprise Edition (EE) adds Support for IBM PowerVM V2.1 (VIOS), including NPIV, to the EMC Symmetrix V-Max SRDF July 30, 2010 IBM PowerHA SystemMirror for AIX* Enterprise Edition (formerly HACMP*) V6.1 for AIX V5.3 and V6.1 adds support for IBM PowerVM V2.1 (VIOS), including NPIV, to the EMC Symmetrix V-Max/SRDF.

Tips for implementing NPIV on IBM Power Systems – IBM ...

    https://developer.ibm.com/technologies/systems/articles/au-npiv/
    The biggest disadvantage (that I can see) to using NPIV is the fact that you must install any necessary MPIO device drivers and/or host attachment kits on any and all of the client LPARs. This means that if you have 100 AIX LPARs that all use NPIV and connect to IBM DS8300 disk, you must install and maintain SDDPCM on all 100 LPARs.



How to find Npiv Support Aix 5 3 information?

Follow the instuctions below:

  • Choose an official link provided above.
  • Click on it.
  • Find company email address & contact them via email
  • Find company phone & make a call.
  • Find company address & visit their office.

Related Companies Support