http://wiresizecalculator.net/tables/conduitsupportstable.htm
This table will show the minimum distance between conduit supports based on conduit size and material. Toggle ... These tables list the maximum distance between conduit supports for rigid metallic and non-metallic conduit. Supports for Rigid Metallic Conduit. Source: NFPA 70, National Electrical Code, Table 334.30(B)(2) Conduit Size Distance ...
http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/fasteners_and_fixing/spring_steel_fasteners_NA/NECRequirements.pdf
Reprinted with permission from NFPA 70HB14, the National Electrical Code ... distance cannot be maintained, the cable or raceway ... protection in the form of rigid metal conduit, intermediate metal conduit, or rigid nonmetallic
https://www.electrical-knowhow.com/2013/06/conduit-fittings-and-supports.html
Conduit Fittings and Supports. Types of Conduit Fittings and Supports. ... A conduit nipple is specified by Chapter 9 of the NEC, Note 4 to Tables, as having a maximum length of 24 inches. ... Rigid metallic conduit and electrical metallic tubing both require support. Conduit should be fastened by straps to the ceiling or wall, ...
http://wiresizecalculator.net/calculators/conduitsupports.htm
The Distance Between Conduit Supports Calculator will calculate the maximum allowable distance between supports for rigid metallic and non-metallic conduit. Distance Between Rigid Metallic Conduit Supports. ... Source: NFPA 70, National Electrical Code Table 344.30(B)(2) Distance Between Rigid Non-Metallic Conduit Supports.
https://www.ecmweb.com/cee-news-magazine-archive/article/20894958/code-guide
Nothing in the NEC states that you cannot use the same supports for conduit as for other systems. Although Section 300.11(B) generally prohibits the use of conduit as support for anything else, it does not mention the use of water pipe or other systems (other than ceiling grids and wires) for support of conduit.
https://www.ecmag.com/section/codes-standards/article-370-boxes-conduit-bodies-and-fittings-2
Essentially, rigid metal or intermediate metal conduit can support an enclosure that is supporting a fixture where the conduit is secured within 18 inches of the enclosure. However, if the conditions of this second exception are met, the support distance can be lengthened to 36 inches.
https://www.electriciantalk.com/f5/supporting-emt-connectors-35939/
Mar 16, 2012 · We run tons of 3/4 EMT and I have very politely asked each one of them to show me where this is stated in the NEC. After much searching the fallback answer is always "the inspector insists on us putting a support within 3 feet of a coupling". End of discussion. If I am missing something I would appreciate a code number so I can change my ways.
https://www.jadelearning.com/blog/securing-and-supporting-cables-and-raceways-2/
Jun 21, 2016 · PVC conduit must be secured within 3 ft. of each outlet box, junction box, device box, conduit body, or other conduit termination. PVC must be supported every 3 ft. for trade sizes ½ inch through 1 inch. The support distance increases as the conduit size gets larger.
https://www.ecmag.com/section/codes-standards/article-370-boxes-conduit-bodies-and-fittings
The radius of a circle is the distance from the center to the outside edge of that circle. ... A single conduit cannot support an enclosure, except for a conduit body constructed with only one conduit entry. ... MILLER, owner of Lighthouse Educational Services and author of Illustrated Guide to the National Electrical Code, can be reached by ...