https://www.cablinginstall.com/connectivity/article/16465209/datacomm-cables-and-the-2017-national-electrical-code
While a 75-degree C rated Type CL2P-LP (0.6A), 22 AWG cable is permitted to carry up to 0.6 ampere per conductor when the cable is installed in a cable tray with hundreds of cables, the simplified ampacity table (which only includes 75-degree C rated cables) shows that a 75-degree C rated Type CL2P, 22 AWG cable is permitted to carry up to 1.2 amperes in a 19-cable bundle.
https://allstarce.com/wp-content/uploads/2016/12/2017-NEC-Code-Ch-3-Article-300-2.pdf
NEC 2017 Code Changes Chapter 3 - Wiring Methods and Materials Changes from the 2014 code are highlighted in yellow. ARTICLE 300 - General Requirements for Wiring Methods and ... conduit or tubing that is used to provide cable support or protection against physical damage.
https://www.cabletrays.org/codes-and-standards/
NFPA 70 – The National Electrical Code covers the installation requirements for the safe application of cable tray systems including ladder, ventilated trough, ventilated channel…
https://www.electricallicenserenewal.com/Electrical-Continuing-Education-Courses/NEC-Content.php?sectionID=290.0
The most common method used to secure and support nonmetallic-sheathed cables is staples but the NEC also allows cable ties, straps, hangers, or similar fittings. Not all cable ties are created equal. Some have only been evaluated to secure or position a cable. UL considers a cable tie a “cable positioning device” and certifies them to UL 62275.
https://www.wireandcabletips.com/hanging-tough-with-vertical-cable-supports/
Jan 08, 2019 · The National Electric Code (NEC) calls out specific installation methods for long vertical runs. NEC Article 300.19 (Supporting conductors in vertical raceways) states that cable support is needed at the top of a long raceway, with intermediate supports installed at specified lengths according to a formula based on the size of the wire, some as frequently as every 40 ft, as seen in the …
https://www.ecmweb.com/national-electrical-code/qa/article/20903258/stumped-by-the-code-rules-for-supporting-and-securing-metalclad-type-mc-cable
(2) Not more than 6 ft long from the last point of cable support to the point of connection to a luminaire or electrical equipment within an accessible ceiling. For the purposes of this section, Type MC cable fittings are permitted as a means of cable support (Figure).
https://www.ecmweb.com/national-electrical-code/qa/article/20888229/code-qa
Type MC cable can be unsupported where the cable is: 1) Fished through concealed spaces in finished buildings or structures, where support is impracticable, or 2) Not more than 6 ft long from the last point of cable support to the point of connection to luminaires or …
http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/fasteners_and_fixing/spring_steel_fasteners_NA/NECRequirements.pdf
Reprinted with permission from NFPA 70HB14, the National Electrical Code ... for cable support, must be secured at both ends. When independent wires are used in fire-rated assemblies, they must be distinguishable from those wires that are part of the fire-rated assembly.
http://www.codebookcity.com/codearticles/nec/necarticle300.htm
National Electrical Code Top Ten Tips: Article 300 -- Wiring Methods. Based on the 2017 NEC. by Mark Lamendola. Please note, we do quote from copyrighted material. While the NFPA does allow such quotes, it does so only for the purposes of education regarding the National Electrical Code. This article is not a substitute for the NEC.