Searching for Mc Cable Support information? Find all needed info by using official links provided below.
https://www.eaton.com/us/en-us/catalog/support-systems/cable-support-fasteners.html
Eaton B-Line series cable support fasteners are used to support metal clad cables (MC), armored cables (AC), non-metallic cables and flexible conduit in new or retrofit commercial construction. These rigid cable support fasteners are used when supporting cable on metal or wood wall studs, wire, purlins and more.
https://www.ecmweb.com/national-electrical-code/qa/article/20888229/code-qa
Type MC cable can be unsupported where the cable is: 1) Fished through concealed spaces in finished buildings or structures, where support is impracticable, or 2) Not more than 6 ft long from the last point of cable support to the point of connection to luminaires or …
https://iaeimagazine.org/magazine/features/vertical-mc-cable-support-in-the-2014-nec/
UL 1569 is the product standard used to list MC cable, and there is no special test in the standard for MC cable used in a vertical installation. Additionally, there are no requirements in the NEC for supporting the conductors inside the cable, unlike the requirements for conductors in raceway.
https://www.graybar.com/store/en/gb/fasteners-and-hardware/hangers/cable-support
Shop our inventory of Cable Support online. Graybar is your trusted distributor for Hangers.
https://forums.mikeholt.com/threads/support-of-mc-cable-above-suspended-cieling.89397/
Aug 19, 2011 · I was failed on an above ceiling inspection because I supported mc cable on the ceiling grid wire 300.11.2 Exception allows this in a non fire rated ceiling as long as it is installed per the manufacture's instructions. Here's the tricky part...According to the manufacture they do not have...
https://www.mcmaster.com/cable-supports
To create your password, open the email from McMaster-Carr Sales. If you do not receive the email or have questions, you may contact us for assistance. ... Also known as bus drop grips, these grips support cable weight and relieve tension. They also damp vibration in hanging runs of cable, rod, and tubing.
https://www.platt.com/platt-electric-supply/Conduit-Cable-Snap-In-Supports/nVent-Caddy/MAC2/product.aspx?zpid=373510
nVent Caddy MAC2 Snap-In Cable Support, For MC/AC Cable and Flexible Conduit Snap-In Support, MC/AC Cable Flexible Conduit, Metal or Wood Stud and Up to …
http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/fasteners_and_fixing/spring_steel_fasteners_NA/CC-Multi-RunCableCarrier.pdf
Multi-Run Cable Carrier for MC/AC Cable Note: An independent means of support is required by NEC Article 300.11. Refer to pages 221-222 for additional support methods. UPC/Part Catalog Cable Diameter & Box Number Number Number Of Runs Qty. 78205144075 BRC51-W2.430" to .560" 25 Up To 4 Runs 78205144076 BRC52-W2.430" to .560" 25 Up To 9 Runs
https://www.ecmweb.com/national-electrical-code/qa/article/20903258/stumped-by-the-code-rules-for-supporting-and-securing-metalclad-type-mc-cable
Type MC cable must be supported at intervals not exceeding 6 ft. Cables installed horizontally through wooden or metal framing members are considered secured and supported if such support doesn’t exceed 6-ft intervals [330.30(C)]. Type MC cable can be unsupported and unsecured where [330.30(D)]: