https://www.ecmweb.com/national-electrical-code/qa/article/20888229/code-qa
Type MC cable can be unsupported where the cable is: 1) Fished through concealed spaces in finished buildings or structures, where support is impracticable, or 2) Not more than 6 ft long from the last point of cable support to the point of connection to luminaires or …
http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/fasteners_and_fixing/spring_steel_fasteners_NA/NECRequirements.pdf
NEC Requirements 218 NEC Requirements Reprinted with permission from NFPA 70HB14, ... for cable support, must be secured at both ends. When independent wires are used in fire-rated assemblies, they must be distinguishable from those wires that are part of the fire-rated assembly.
https://www.ecmag.com/section/systems/review-metal-clad-cable-requirements
There are a number of changes in the 2002 National Electrical Code (NEC) regarding Metal-Clad (Type MC) Cable that should be reviewed before your next electrical project. In the 1999 NEC, Article 334 covered Type MC Cable; however, in the 2002 NEC, Type MC Cable has been relocated into Article 330. Until you become familiar with the new location in the NEC, it may take some searching to find ...
https://iaeimagazine.org/magazine/features/vertical-mc-cable-support-in-the-2014-nec/
UL 1569 is the product standard used to list MC cable, and there is no special test in the standard for MC cable used in a vertical installation. Additionally, there are no requirements in the NEC for supporting the conductors inside the cable, unlike the requirements for conductors in raceway.
https://www.jadelearning.com/blog/securing-and-supporting-cables-and-raceways-2/
Jun 21, 2016 · MC cable must be supported every 6 ft. MC cable is considered supported when run through metal or wooden framing members. MC cables may be unsupported when (1) fished through concealed spaces in finished buildings, (2) when not more than 6 ft. in length from the last point of cable support to the point of connection to a luminaire or other ...
https://allstarce.com/wp-content/uploads/2016/12/2017-NEC-Code-Ch-3-Article-300-2.pdf
NEC 2017 Code Changes Chapter 3 - Wiring Methods and Materials Changes from the 2014 code are highlighted in yellow. ... , Type MC cable, Type MI cable, nonmetallic-sheathed cable, or other cables, a box or conduit body shall be installed at each conductor ... Steel wire armor cable shall be supported at the top of the riser with a cable support
https://iaeimagazine.org/magazine/features/mc-cable-installations/
Vertical MC cable support. ... In UL 1569, Type MC cable must meet the requirements for tightness of armor on conductors. Cables containing No. 4 AWG or larger conductors must not pull out of a ten foot sample cable suspended vertically for one minute with a 30 lb. weight attached to the conductor more than one-half inch (see photo 9).
https://www.ecmweb.com/national-electrical-code/qa/article/20903258/stumped-by-the-code-rules-for-supporting-and-securing-metalclad-type-mc-cable
Type MC cable must be supported at intervals not exceeding 6 ft. Cables installed horizontally through wooden or metal framing members are considered secured and supported if such support doesn’t exceed 6-ft intervals [330.30(C)]. Type MC cable can be unsupported and unsecured where [330.30(D)]:
http://www.afcweb.com/wp-content/uploads/2015/06/mc-ac-installation.pdf
Installation Instructions for Traditional Type AC & MC Cables ... As noted, AC and MC cable support requirements are waived when the cable is fished. This is a major advantage of AC and MC cable in remodeling work over other wiring products that cannot be fished.