Support Spacing ABS, PE, PVC, Fiberglass and Steel Pipes Maximum distance between supports for ABS, PE, PVC, Fiberglass and Steel Pipes
http://beacomp.com/wp-content/uploads/2018/01/SUPPORT-TECH-PAPER-word.pdf
2. LOCATION of SUPPORTS - When supporting pipe inside of a building, the building steel will provide the easiest support points. If the support spacing is based on the spacing of the structural steel and is found to exceed the calculated support spacing, use a slightly (1/16") thicker pipe wall and re-run spacing calculations. Continue adding wall
https://www.engineeringtoolbox.com/support-spacing-epoxy-pipes-d_788.html
Support spacing for reinforced Epoxy fiberglass pipes. Engineering ToolBox - Resources, ... Maximum distance between epoxy fiberglass pipe supports at different operating temperatures are indicated in the table below. Maximum operating temperature for epoxy pipes should not exceed 300 o F (149 o C). Nominal Pipe Size
https://brittengineering.com/whitepapers/Design-of-FRP-Piping-Systems.pdf
Many piping catalogs include tables that the designer can use to determine support, guide and hanger spacing. The spacings are usually based on a specific gravity of 1.2, a liquid temperature of 160 or 180 degrees F, and a limited deflection of 1/2". This ... A family of special FRP pipe support designs is illustrated in “Support Design”.
https://www.enggcyclopedia.com/2012/06/spacing-pipe-supports/
For fiber reinforced plastic pipe (FRP), support spacing in liquid service would vary from around 11-ft for 2" pipe to 22-ft for 8" pipe; and for gas service 17-ft for 2" to 40-ft for 8". For high density polyethylene (HDPE) the spacing would vary from 7-ft for 4" pipe with SDR (diameter over thickness) of 11.0, to 16-ft for 24" pipe.
http://www.ifs-frp.com/wp/pdf/technical-bulletins/how-far-apart-supports.pdf
considered in designing the supports and support spacing. Support spacing needs to be closer for pipe handling a liquid having a specific gravity of 1.22 versus a specific gravity of 1.0. ‚ The operating temperatures (including peak upset temperatures) can also control the support spacing for FRP composite pipe.