http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/fasteners_and_fixing/spring_steel_fasteners_NA/NECRequirements.pdf
Support wires that do not provide secure ... (24 in.) without maintaining spacing and are not installed in raceways, the allowable ... protection in the form of rigid metal conduit, intermediate metal conduit, or rigid nonmetallic conduit having a length not exceeding 3.05 m.
https://steeltubeinstitute.org/steel-conduit/resources/installation-guides/support-raceways/
Steel conduit / tubing run through openings in metal or wood studs : Such openings can be used for support where the openings are no more than 10 feet apart. Secure fastening at termination points is …
https://www.jadelearning.com/blog/securing-and-supporting-cables-and-raceways-2/
Jun 21, 2016 · EMT must be secured at least every 10 ft. and within 3 ft. of every outlet box, junction box, device box, cabinet, conduit body, or other termination. An exception allows EMT to be fastened up to 5 ft. apart if structural members like joists or rafters do not permit fastening every 3 ft.
https://www.electriciantalk.com/f31/emt-support-144370/
Feb 11, 2016 · "12-1010 (1)All rigid metal conduit of one size shall be securely attached to hangers or to a solid surface with the maximum spacings of the points of support not greater than(a)1.5 m for 16 and 21 trade size conduit"
https://www.ecmweb.com/cee-news-magazine-archive/article/20894958/code-guide
Both of these require that the conduit be “securely fastened in place.” They do not say, “directly attached to the structure.” Generally, the maximum support spacing requirement for RMC (rigid metallic conduit) of trade size 1 is 10 ft, but for straight runs with threaded couplings, this spacing is increased to 12 ft.
http://wiresizecalculator.net/tables/conduitsupportstable.htm
This table will show the minimum distance between conduit supports based on conduit size and material. Toggle navigation ... These tables list the maximum distance between conduit supports for rigid metallic and non-metallic conduit. Supports for Rigid Metallic Conduit. Source: NFPA 70, National Electrical Code, Table 334.30(B)(2) Conduit Size
http://wiresizecalculator.net/calculators/conduitsupports.htm
Distance Between Rigid Metallic Conduit Supports Enter the information below to calculate the distance between supports. Select conduit size: - ½" - ¾" 1" 1¼" - 1½" 2" - 2½" 3" and larger
https://diy.stackexchange.com/questions/117796/unistrut-spacing-electrical-conduit
Support is required as specified for the conduit - unistrut does not make any difference in the required support spacing. For EMT, the required support is within 3 feet of each termination , …
https://quizlet.com/164281298/nec-2017-support-and-securing-requirements-flash-cards/
Start studying NEC 2017 Support and Securing Requirements. Learn vocabulary, terms, and more with flashcards, games, and other study tools.
https://steeltubeinstitute.org/steel-conduit/wp-content/uploads/sites/4/2013/04/ConGuide.pdf
metal conduit (RMC), steel intermediate metal conduit (IMC), and steel electrical metallic tubing (EMT). Conduit with a supplementary PVC coating is also included. These conduits are used as raceway systems for electrical wiring in residential, commercial, and industrial occupancies. This standard includes information on fittings and other ...