Distance Between Conduit Supports - Wire Size Calculator

    http://wiresizecalculator.net/tables/conduitsupportstable.htm
    These tables list the maximum distance between conduit supports for rigid metallic and non-metallic conduit. Supports for Rigid Metallic Conduit Source: NFPA 70, National Electrical …

Distance Between Conduit Supports Calculator

    http://wiresizecalculator.net/calculators/conduitsupports.htm
    The Distance Between Conduit Supports Calculator will calculate the maximum allowable distance between supports for rigid metallic and non-metallic conduit. Distance Between Rigid Metallic Conduit Supports. ... NFPA 70, National Electrical Code Table 344.30(B)(2)

Article 370 - Boxes, Conduit Bodies, and Fittings ...

    https://www.ecmag.com/section/codes-standards/article-370-boxes-conduit-bodies-and-fittings-2
    Essentially, rigid metal or intermediate metal conduit can support an enclosure that is supporting a fixture where the conduit is secured within 18 inches of the enclosure. However, if the conditions of this second exception are met, the support distance can be lengthened to 36 inches.

Conduit Fittings and Supports ~ Electrical Knowhow

    https://www.electrical-knowhow.com/2013/06/conduit-fittings-and-supports.html
    Conduit should be fastened by straps to the ceiling or wall, or supported on hangers from the ceiling at least every 10 feet (Figure 11). Conduit should be fastened within 3 feet of a box (5 feet of unbroken lengths are allowed if structural members do not permit fastening within 3 feet).

Conduit Supports and Installation Methods - tpub.com

    http://constructionmanuals.tpub.com/14027/css/Conduit-Supports-and-Installation-Methods-118.htm
    LOCATION OF CONDUIT SUPPORTS The Code states that rigid-metal conduit will be firmly secured within 3 feet of each outlet box, junction box, cabinet, or fitting. The Code permits this distance to be increased to 5 feet where structural members do not readily permit fastening within 3 feet.

Securing and Supporting Cables and Raceways – Jade Learning

    https://www.jadelearning.com/blog/securing-and-supporting-cables-and-raceways-2/
    Jun 21, 2016 · PVC must be supported every 3 ft. for trade sizes ½ inch through 1 inch. The support distance increases as the conduit size gets larger. For example, 2 inch PVC conduit can be supported every 5 ft; 6 inch PVC conduit can be supported every 8 ft. See Table 352.30.

GUIDELINES FOR INSTALLING STEEL CONDUIT/TUBING

    https://steeltubeinstitute.org/steel-conduit/wp-content/uploads/sites/4/2013/04/ConGuide.pdf
    metal conduit (RMC), steel intermediate metal conduit (IMC), and steel electrical metallic tubing (EMT). Conduit with a supplementary PVC coating is also included. These conduits are used as raceway systems for electrical wiring in residential, commercial, and industrial occupancies. This standard includes information on fittings and other ...

PIPE/CONDUIT SUPPORTS - Strut and Supply Inc

    http://www.strutandsupply.com/files/5413/3366/3397/Unistrut%20General%20Catalog%206%20-%20Pipe%20Conduit%20Supports.pdf
    are designed for the support of electrical and mechanical services. Supports to meet nearly every requirement can be attained using Unistrut Metal Framing components. ... Pipe/Conduit Supports 105 ¼ &KDQQHO7HOHVWUXW1XWV +DUGZDUH *HQHUDO )LWWLQJV3LSH &RQGXLW 6XSSRUWV (OHFWULFDO )LWWLQJV&RQFUHWH ,QVHUWV