Sep 17, 2019 · Modbus I/O servers, which are in the LabVIEW DSC and LabVIEW Real-Time modules, provide a high-level engine for communicating over Modbus. Rather than specifying a function code that you wish to send, you register the set of data you would like to access and the I/O server schedules the requests automatically at the specified rate.
https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019LReSAM&l=en-GB
Sep 12, 2019 · LabVIEW 7.1 and later The Modbus Library for LabVIEW is a wrapper for VISA commands. Programming with it requires some knowledge of Modbus function calls to program. This library may not contain as many features you need as the LabVIEW Modbus API or the supported API included with LabVIEW DSC Module.
http://zone.ni.com/reference/en-XX/help/371361R-01/lverror/modbus_error_codes/
The Modbus slave daemon, also known as background process, failed to launch. Contact National Instruments for technical support. −389104: The object that you write exceeds 244 bytes in length. −389103: The object that you specified does not exist in the Modbus slave. Ensure that you specify an object that exists in the Modbus slave.
http://zone.ni.com/reference/en-XX/help/370622R-01/lvmve/modbus_pal/
Home Support Manuals LabVIEW 2017 ... Use the Modbus VIs to create Modbus masters and slaves and to perform read and write operations on Modbus slaves. You must activate the LabVIEW Real-Time Module to use the Modbus VIs on a real-time target. You must activate the LabVIEW Datalogging and Supervisory Control Module to use the Modbus VIs on ...
http://zone.ni.com/reference/en-XX/help/371618K-01/lvdsc/dsc_error_codes/
The Modbus slave device does not support the specified operation. Refer to the documentation of the Modbus slave device for information about supported operations. −1967353904: The response from the Modbus slave device is not readable. Check the serial connection and the communication settings between the Modbus master and slave devices ...
https://documentation.help/Modbus-LabVIEW/documentation.pdf
Modbus LabVIEW Library Help February 2009, 372767A-01 This help file describes the Modbus LabVIEW VI library. For more information about this help file, refer to the following topics: Using Help Important Information Technical Support and Professional Services To comment on National Instruments documentation, refer to the National Instruments ...
https://sourceforge.net/directory/?q=modbus%20library%20for%20labview
modbus library for labview free download. JLibModbus - Java Modbus Library JLibModbus is an implementation of the Modbus protocol v1.1b in java language. The library supports
https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019KzuSAE
Solution Since Modbus uses 16-bit registers to hold values, 32-bit floating point numbers must split between two registers. Modbus does not declare a standard how to represent floating point numbers, so it is possible that a device handles floating point numbers differently than LabVIEW.