https://www.eng-tips.com/viewthread.cfm?qid=451021
Is there a code that prohibits a fitting weld (circumferential weld) from resting on a free pipe support? We have 6" and 12" coated carbon steel pipes that rest on free supports as part of an expansion loop. There are 1/4" teflon pads on these free supports between the support and pipe. Pipe is low pressure fluid (<150 PSIG).
https://groups.google.com/d/topic/materials-welding/7eE0ij8OJ-Y
Circumferential pipe weld joint resting on structural beam in process piping ... The situation is that some of our process piping in refinery division THE CIRCUMFERENTIAL JOINT has come such position that the joint rests on the structural beam. ... Please adjust the pipe support location after approval by your piping design engineering and if ...
https://materials-welding.blogspot.com/2017/03/re-mw26328-circumferential-pipe-weld.html
Mar 30, 2017 · Re: [MW:26328] Circumferential pipe weld joint resting on structural beam in process piping Hi Please adjust the pipe support location after approval by your piping design engineering and if not possible to adjust get concurrence from them for close out.
https://cr4.globalspec.com/thread/82400/Can-support-directly-weld-to-pressure-piping
Dec 27, 2012 · Re: Can support directly weld to pressure piping? 12/26/2012 10:59 AM I would normally avoid welding to a pressure pipe because of possible differential movement such as …
https://materials-welding.blogspot.com/2017/03/re-mw26329-circumferential-pipe-weld.html
Mar 31, 2017 · Re: [MW:26329] Circumferential pipe weld joint resting on structural beam in process piping Generally, piping drawings shall take care of this type of issues during fabrication of pipe spools. It is a very common problem, if you don't have any option to move the support, then before the support cut and add one pup piece pipe and do all welding ...
https://groups.google.com/d/msg/materials-welding/7eE0ij8OJ-Y/s1ixboqWAwAJ
Google Groups. Re: [MW:26299] Circumferential pipe weld joint resting on structural beam in process piping. M.Sathiya Narayanan: Mar 29, 2017 8:16 PM: Posted in group: Materials & Welding: ... We need your kind support based on your experience and any code/std references.
http://pipingdesigners.com/forum/the-technical-forum/387-minimum-spacing-between-circumferential-welds-joints.html
hola a todos/ HELLO to alls i'm new in this place but i got a one question. what is the Minimum spacing between circumferential welds joints, according to which norm or code (ASME, API OR WHAT HANDBOOK) THANKS/GRACIAS MIL DISCULPAS MI INGLES ES MUY MALO
How to find Circumferential Weld Resting On Pipe Support information?
Follow the instuctions below:
- Choose an official link provided above.
- Click on it.
- Find company email address & contact them via email
- Find company phone & make a call.
- Find company address & visit their office.