Cavity Dpc Support

Searching for Cavity Dpc Support information? Find all needed info by using official links provided below.


Type J DPC Support and Closer - Cavity Trays Limited

    https://www.cavitytrays.com/damp-proofing/view/1/27/1/type-j-dpc-support-and-closer
    The conventional cavity parapet is normally terminated with copings, under which a DPC is bedded and positioned. The width of the DPC must be sufficient to slightly overhang the width of the parapet masonry. Support of the DPC is required where it crosses the cavity. The Type J is designed for such purposes. J1 = 130mm x 30mm x 2mm/2.5mm.

Type J DPC Support and Closer - DPC Products Direct

    https://www.dpcproductsdirect.com/products/type-j-dpc-support-and-closer/27/
    The conventional cavity parapet is normally terminated with copings, under which a DPC is bedded and positioned. The width of the DPC must be sufficient to slightly overhang the width of the parapet masonry. Support of the DPC is required where it crosses the cavity. The Type J is designed for such purposes. J1 = 130mm x 30mm x 2mm/2.5mm.

Type J DPC Support and Closer - Cavity Trays Ltd

    https://www.ribaproductselector.com/Product.aspx?ci=1605&pr=CavityTrays-TypeJDPCSupportandCloser
    Cavity closer for masonry beneath copings at parapets and eaves. At parapet locations the cavity closer provides support for the DPC beneath copings. The closer is available with or without integral insulation, which when included, provides a thermal break. Features: Fulfils the DPC support requirements illustrated in BS 5628-3.

Type J2 DPC Cavity Support and Closer 100mm - 2.4m Length ...

    https://www.roofingsuperstore.co.uk/product/type-j2-dpc-cavity-support-and-closer-100mm-24m-length.html
    The conventional cavity parapet is normally terminated with copings, under which a DPC is bedded and positioned. The width of the DPC must be sufficient to slightly overhang the width of the parapet masonry. Support of the DPC is required where it crosses the cavity. The Type J is designed for such purposes. J1 = 130mm x 30mm x 2mm/2.5mm.

Specifi cations TYPE J - cavitytrays.com

    https://www.cavitytrays.com/pdf/27-Type-J.pdf
    The conventional cavity parapet is normally terminated with copings, under which a DPC is bedded. The width of the DPC is required to be sufficient to slightly overhang the width of the parapet masonry. Support of the DPC is required where it crosses the cavity. The Type J Support and Closer is designed for such purposes.

NHBC Risk Guide Parapets and copings

    http://www.nhbc.co.uk/zmedia/filedownload,65787,en.pdf
    cavity closer and support to DPC lead flashing, with welted ends, built under tray and dressed over DPC cavity tray with stop ends DPC under coping turned up wall behind flashing coping outer leaf inner leaf continuous metal coping with integral upstand stop end

Xtra-Load DPC Joint Support System - Icopal

    http://www.icopal.co.uk/Products/Structural_Waterproofing/Damp_Proof_Course/DPC_Products/Xtra_DPC_Accessories/Xtra_DPC_Joints.aspx
    Xtra-Load DPC Joint Support System is manufactured from a 100mm wide strip of flexible polymer membrane with an FR expanded polystyrene wedge fixed to the back to give support across the cavity, an integral drip prevents moisture transmission across the cavity.

Masonry cavity walls

    https://pim.knaufinsulation.com/files/download/3.1.1-masonry-cavity-walls.pdf
    Masonry Cavity Walls 311 Technical Support Team 01744 766666 www.knaufinsulationcouk 311 125. Masonry cavity walls ... vertically at an open cavity, a vertical dpc must be fitted up the inside face of the outer leaf to ensure that any mortar droppings on exposed

Preformed Cavity Tray Units - Visqueen Building Products ...

    https://www.visqueen.com/products/preformed-units/preformed-cavity-tray-units
    Dedicated free design support service for project specific preformed units Both damp proofing and gas proofing units available An integral part of the Zedex High Performance Damp Proofing System, the Visqueen range of standard preformed cavity tray units simplify detailing at …

6.1.17 DPCs and cavity trays - NHBC Standards 2020 NHBC ...

    https://nhbc-standards.co.uk/6-superstructure-excluding-roofs/6-1-external-masonry-walls/6-1-17-dpcs-and-cavity-trays/
    A DPC should be provided behind a doorstep where it is higher than a wall DPC. Sills: Where precast concrete or similar sills incorporate joints or are of a permeable material, a DPC should be provided beneath them for the full length and be turned up at the back and the end of the sill. Jambs in cavity



How to find Cavity Dpc Support information?

Follow the instuctions below:

  • Choose an official link provided above.
  • Click on it.
  • Find company email address & contact them via email
  • Find company phone & make a call.
  • Find company address & visit their office.

Related Companies Support